Features:
1. With USB download function, with RS232 interface, curve software, no recorder required;
2. With a vacuum glass observation window, more effective direct observation function;
3. Refrigerant servo valve flow calculation control, saving 30% of electricity, with dwell time sleep function, energy saving more than 50%;
4. The controller's anti-electromagnetic interference has been certified by SGS; it has software matching with 32 digits or more, and has the functions of secondary development and software upgrade;
5. Passed ISO-9001 quality certification;
6. Defrost cycle (800 cycles of defrost once, each defrost is guaranteed to be within 2 hours, and the integration test achieves 25% energy saving and electricity saving).
the test standards:
GB/T2423.2-89 ………………高温试验方法Bb GB/T2423.3 ………………恒定湿热试验方法
IEC60068-2-38 ………………温度循环 GJB150.4-86………………军用设备环境试验方法低温试验
IEC60068-2-78 ………………恒定湿热 GJB150.3-86………………军用设备环境试验方法高温试验
MIL-STD-202G-103B ……… 湿度测试 GB/T2423.34-2005……… 温度、湿度组合循环试验法
IEC60068-2-30 ………………湿热温度循环 GJB150.9-86………………军用设备环境试验方法湿热试验
EIA-364-31C …………………耐湿性
Specifications:
Capacity |
80L |
150L |
408L |
800L |
Temperature range |
-40°C ⇔+150°C |
|||
Heating time |
-40℃ ↑ +150 ℃: ≈50min |
-40℃ ↑ +150 ℃: ≈50min |
-40℃ ↑ +150 ℃: ≈40min |
-40℃ ↑ +150 ℃: ≈0min |
Cooling time |
+20℃ ↓ -40 ℃: ≈60min |
+20℃ ↓ -40 ℃: ≈60min |
+20℃ ↓ -40 ℃: ≈60min |
+20℃ ↓ -40 ℃: ≈70min |
Inner size |
W 400 mm x H 500 mmx D400 mm |
W 500 mm x H 600 mmx D 500 mm |
W 800 mm x H 850 mmx D 600 mm |
W 1000 mm x H 1000 mmx D 800 mm |
Dimensions |
W 650 mm x H 1615mm x D1205 mm |
W700 mm x H 1625mm x D1530 mm |
W 1000 mm x H 1925mm x D1630 mm |
W1200 mm x H 2090mm x D1830 mm |
Uniform temperature |
≤±2.0℃ |
|||
Temperature fluctuation |
≤±0.5℃ |
|||
Humidity range |
10~98%RH |
|||
Humidity deviation |
≤ ±3.0%RH(Humidity > 75%RH):≤ ±5.0%RH(Humidity ≤ 75%RH) |